Menu Hledej For Partners +420 545 537 111 mail@bmt.cz
Close

VACUCELL 22 - EVO line

Product images are for illustrative purposes only and may differ from the actual product.
  • fast, gentle, environmentally friendly - laboratory drying oven for higher demands
  • chamber volume 22 litres
  • temperature range from 5°C above ambient to 250/300°C
  • characterized by noiseless operation and gentle sample heating in the chamber, offering high-quality and safe heating and drying of samples up to constant weight
  • high operation comfort, precise temperature control and short chamber temperature equalization times after the door opening
  • suitable for perfect drying of thermally labile and oxidation sensitive materials, complicated shapes, drying of samples to constant weight, etc. in vacuum
  • wide selection of optional equipment and accessories (e.g. supplementing the “Vacustation” base with the option of installing a selected type of a vacuum pump,…)
I am interested in VACUCELL 22 - EVO line
Technical parameters

Interior of stainless steel material No. 1.4571

volume 22 l
depth 260 mm
width 340 mm
height 300 mm

Tray

number 2 pcs
racks max. 5 pcs

Minimal Shelves distance

height 36 mm

Usefull dim. of shelf

width × depths 280 × 236 mm

External dimensions (including door and handle)

depth 500 mm
width 560 mm
heights(incl. foots) 780 mm

Package dimensions

depth 660 mm
width 720 mm
height (incl. palette) 960 mm

Weight

brut 91 kg
net 68 kg

Working temperature (regulation start)

from 5 °C over ambient temp to 250 °C

Temp. deviations acc. to DIN 12 880 Part 2 from working temp – Al shelves pressure 5–10 mbar**

in time to: 0,4 ± °C
in space, temperature 100 °C do: 2 ± °C
in space, temperature 200 °C do: 5 ± °C

Temp. deviations acc. to DIN 12 880 Part 2 from working temp – ss shelves pressure 5–10 mbar**

i time to: 0,5 ± °C
in space, temperature 100 °C do: 10 ± °C
in space, temperature 200 °C do: 18 ± °C

Time of rise onto 98 % voltage 230 V – (Al shelves pressure 5–10 mbar)

onto temp 100 °C 60 min
onto temp 200 °C 80 min

Time of rise onto 98 % voltage 230 V – (shelves pressure 5–10 mbar)

onto temp 100 °C 130 min
onto temp 200 °C 170 min

Heat radiation

at 100 °C 150 W
at 200 °C 300 W

Vacuum connection

ball valve with internal thread 1/4 ''
measuring acces (ISO KF) 40 mm
vacuum connection measuring DN (ISO KF) Including hose end Ø 12 mm 16 mm

Electric parameters – mains 50/60 Hz

nominal voltage 230 V
mains 50/60 Hz 0,8 kW
current 3,5 A
input in stand by mode 11 W

Max. permissible load of the shelves

inside the oven 35 kg/oven
per shelves 20 kg

Note: All technical data are related to 22 °C of ambient temperature and ±10 % voltage.

Changes in the design and make reserved.
The values may differ depending on specific charge and media parameters.
Downloads Optional equipment
Optional equipment
  • Notice
    Product images are for illustrative purposes only and may differ from the actual product.
  • Safety thermostat class according to DIN 12880 (user adjustable)
    The protective thermostat is used to protect the exposed material, the device itself and its surroundings in the event of an unexpected course of regulation or failure. The temperature in the chamber is measured and evaluated by an independent control block. When the limits of the protection thermostat are exceeded, the heaters are disconnected from the mains voltage and the heating of the cabinet is stopped.
    Safety thermostat class according to DIN 12880 (user adjustable)
  • Stainless steel shelf
    Shelf made of stainless steel AISI 304, suitable for placing a small-size sample in the chamber.
    Stainless steel shelf
  • Aluminium shelf
    Aluminum shelves guarantee fast and efficient heat transfer to the samples
    Aluminium shelf
  • Door lock (same key for order)
    Mechanical door lock for the basic level of protection. It is supplied with two keys.
    Door lock (same key for order)
  • Door lock (different keys for order)
    Mechanical door lock for the basic level of protection. It is supplied. Within one set of devices, different lock inserts are distinguished.
    Door lock (different keys for order)
  • Automatic door lock
    The device is equipped with an electromagnetic mechanism for blocking-locking the door. Can be operated manually or automatically.
    Automatic door lock
  • Stainless steel shell
    Stainless steel design of the device housing, including AISI 304 stainless steel handle
    Stainless steel shell
  • Stainless steel interior DIN 1.4301/AISI 304
    Standard chamber design made of stainless steel AISI 304
    only the inner equipment of the chamber, the chamber always from DIN 1.4571/AISI 316 Ti
    Stainless steel interior DIN 1.4301/AISI 304
  • Stainless steel interior DIN 1.4404/AISI 316L
    Optional chamber design in stainless steel AISI 316 with higher chemical resistance
    only the inner equipment of the chamber, the chamber always from DIN 1.4571/AISI 316 Ti
    Stainless steel interior DIN 1.4404/AISI 316L
  • Flexible PT sensor
    Additional movable sensor in the chamber for measuring the temperature at the sample or in the sample. It is not used for temperature control. The additional sensor data is shown on the display as an additional temperature value. (max. 4 pc)
    Flexible PT sensor
  • Flexible PT sensor at the temperature of 300°C
    Additional movable sensor for higher temperatures.

    (consultation required)
    Flexible PT sensor at the temperature of 300°C
  • Access port CF Ø 40 mm
    Rotational stainless steel access port DN 40 CF located on the back of the chamber
    Access port CF Ø 40 mm
  • Access port - special shape or position
    The port with a stainless steel body allows the wires, sensors, etc. to be threaded into the chamber. Optional size, shape or position in the wall.
    (consultation required)
    Access port - special shape or position
  • Interior lighting
    Heat-resistant interior lighting with touch switch.
    Interior lighting
  • Special housing modification for insulator technologies
    A set of mechanical modifications of the device for tight connection to the laboratory insulator.
    (consultation required)
    Special housing modification for insulator technologies
  • Modification without particles
    Sealing of the chamber and fan to prevent particles from entering the chamber from the outside.
    (consultation required)
    Modification without particles
  • Vacustation
    Painted cabinet in the design of the device for placing the pump, located under the Vacucell device of the given size.
    (except the volume 22)
    Vacustation
  • Vacuum pump Vacubrandt MZ2CNT+AK+EK
    Vacuum pump Vacubrandt MZ2CNT+AK+EK
  • Vacuum pump Vacubrandt MD4CNT+AK+EK
    Vacuum pump Vacubrandt MD4CNT+AK+EK
  • Vacuum pump on request
    (consultation required)
    Vacuum pump on request
  • Special electric access port
    (Je potřeba konzultace)
    Special electric access port
  • Aggressive heating
    Service functions allowing to increase or decrease start times. This function can change the properties of the device.
    Aggressive heating
  • ECO PLUS
    The optional extension for Eco devices expands the number of segments from 2 to 8 for one program and allows temperature ramps to be defined within the program.
    ECO PLUS
  • Internal socket max. 100°C (230 V, 3 A protection, IP67)
    Vacuum tight socket (nominal voltage 230 V, fuse 3 A, protection IP67) is located inside the chamber on the side wall.
    (consultation required)
    Internal socket max. 100°C (230 V, 3 A protection, IP67)
  • Potential-free contact (BMS) – remote alarm 24V/1A
    The potential-free contact is connected to a connector to which voltages up to 24 V / 1 A can be connected. It is used to implement a remote alarm (in Anglo-Saxon countries it is referred to as BMS relay - Building Management System relay) - i.e. a remote line that is interrupted by a built-in relay potential-free contact, the fault information is transmitted to rooms other than the one in which the temperature box is located. The relay opens in all error states reported on the display.
    Potential-free contact (BMS) – remote alarm 24V/1A
  • Emergency stop button
    Hardware main switch with a lockable system, which, if necessary, interrupts the connection of electric power.
    (consultation required)
    Emergency stop button
  • National design of the electric plug
    Power supply termination supply according to the national standard
    (consultation required)
    National design of the electric plug
  • Operation temperature shift
    Increasing the maximum working temperature to 300 °C
    Operation temperature shift
  • Digital vacuum display (0.1-1100 mbar)
    Digital vacuum display (0.1-1100 mbar)
  • Analogue output 4-20mA
    The device contains a converter of the required quantity (temperature, CO2 concentration) to a 4-20 mA output, connected to a connector connection. It is not a quantity read by the instrument itself and converted to 4-20 mA. The customer processes the value himself and must also ensure the calibration of the sensors. Data cannot be collected using WarmComm.
    Analogue output 4-20mA
  • Software Warmcomm 4 Basic (B)
    "WarmComm 4 is designed to record the course of device control. The program uses the Server - Client arrangement. In this configuration, the monitored devices are connected to a Server that records and stores data obtained during control. Individual users then access this data through the Client. This arrangement can be implemented within a single PC, within a LAN or via the Internet or within a local network."
    Software Warmcomm 4 Basic (B)
  • Software Warmcomm 4 Professional (P)
    "WarmComm 4 is designed to record the course of device control. The program uses the Server - Client arrangement. In this configuration, the monitored devices are connected to a Server that records and stores data obtained during control. Individual users then access this data through the Client. This arrangement can be implemented within a single PC, within a LAN or via the Internet or within a local network."
    Software Warmcomm 4 Professional (P)
  • Software Warmcomm 4 FDA (F)
    "WarmComm 4 is designed to record the course of device control. The program uses the Server - Client arrangement. In this configuration, the monitored devices are connected to a Server that records and stores data obtained during control. Individual users then access this data through the Client. This arrangement can be implemented within a single PC, within a LAN or via the Internet or within a local network."
    Software Warmcomm 4 FDA (F)
  • External printer
    Use the EPSON TM-T20III to print the report.
    External printer
  • Software PrinterArchiv
    The Printer Archive program is intended for recording from the machine's print output. It serves as a direct replacement for a physical printer. The recording is in a fixed, preset format. Wider options for handling the recorded protocol, including archiving or printing to a desktop PC printer. Ordinary PCs with Windows XP and higher operating software can handle the hardware requirements. One free RS 232 (COM) port is required for each connected device. The maximum length of the connecting cable is 15 m. For more detailed requirements towards HW, get information from the dealer.
    Software PrinterArchiv
  • Internal temperature measurement, 1 point
    Validation of the temperature distribution in the chamber at the user's reference temperature (1 point).
    Internal temperature measurement, 1 point
  • Measurement of temperature distribution, 3 points
    Validation of the temperature distribution in the chamber at the user's reference temperature (3 points).
    Measurement of temperature distribution, 3 points
  • Temperature measurement, 9-point (DIN 12880)
    Validation of the temperature distribution in the chamber at the user's reference temperature (9 points).
    Temperature measurement, 9-point (DIN 12880)
  • Validation documentation
    IQOQ dokumentation
    Validation documentation
  • Ethernet communication port for ECO
    Optional equipment extends the communication capabilities of ECO devices with Ethernet.
    Ethernet communication port for ECO

Are you interested in VACUCELL 22 - EVO line?

Call us, visit us or fill in the contact form and we will reply by the next working day.

Call Us
+420 545 537 111 Monday - Friday 8.00 am to 4.00 pm
We are out of office
Visit Us
BMT Medical Technology s.r.o. Cejl 157/50, Zábrdovice, 602 00 Brno View a Route on the map

Please fill in the non-binding inquiry




I am Interested in